Enquire about the r-weather
Receive advice about product specifications and find the right Boschung vehicle and equipment for your needs.
We have a new career page! Check it out and join the team
Close
Combining all the measuring functionalities of the most important weather conditions, the r-weather is a unique and self-cleaning instrument. Visibility, precipitation type, intensity and quantity, air temperature, relative humidity, dew point and frost point, barometric pressure, wind speed and wind direction are all measured from one tool, easy to install and operate.
With the ability to measure the level of reduced visibility and air temperature, the r-weather detects the very dangerous freezing fog.
El r-weather proporciona los parámetros meteorológicos y de visibilidad actuales necesarios para un análisis exhaustivo de las condiciones atmosféricas:
An integrated compressor in the back of the r-weather automatically cleans the optical part of the r-weather by blasting pressurized air while an internal heating system prevents any ice formation. Done at predefined regular intervals or after detection of debris, the cleaning process ensures the device is working perfectly at all time.
The r-weather is a very compact instrument with standard assembly handles easily mounted on a mast. Just one cable links the device to the data processor unit also if a separate wind speed/direction sensor is integrated.
520 mm
260 mm
170 mm
approx. 8 kg (full version)
aluminum support & IR-resistant plastic case
Subject to technical modifications without prior notice.
-40… +85 °C
±0.1 °C (from -10 to +10 °C); else ±0.2 °C
0.1 °C
0… 100% RH
±2%
0.1% RH
0… +85 °C
±0.3 °C (from -10 to 10 °C)
0.1 °C
Rain, snow, mixed rain/snow, ice grains, fog, mist, drizzle, clarity
Intensity: 0-200 mm/h
Accumulation in mm (0…1000)
±15%
Rain 0.1 mm/h
Snow 1 mm/h
10 - 4,000 m
< 100 m ± 10 m; beyond ± 10%
1 m
300… 1,200 hPa
0.5 hPa @ 20°C
0.1 hPa
Mechanical: 0… 80 m/s Ultrasonic: 0… 60 m/s
Mechanical: ± 1% of the measured value
Ultrasonic: ± 2% of the measured value
Mechanical: 0.01 m/s Ultrasonic: 0.01 m/s
Mechanical: 0… 359° Ultrasonic: 0… 359°
Mechanical: 2° Ultrasonic: 2°
Mechanical: 1° Ultrasonic: 1°
12… 24 Vdc / < 80 mA (with heater: <550 mA)
Minimum version: 2 W min. @ 24 Vdc Full version: 25 W max. @ 24 Vdc
RS232 & RS485
Boschung proprietary or open text protocol using ASCII codes
compressed air < 0.6bar
Wavelength 980 nm
-40… 85 °C
IP67 (DIN 40050)
EN 61000-6-2:1999, EN 61000-4-2:1995, EN 61000-4-3:1996, EN 61000-4-4:1995, EN 61000-4-6:1996
Receive advice about product specifications and find the right Boschung vehicle and equipment for your needs.