Boschung

IT-SENS

Reporting of the surface condition

  • Situation
    • Boschung
      Airport
    • Boschung
      Highway and Road
    • Boschung
      City and Municipality

Specifications

Surface condition

  • Dry
  • Moist
  • Wet
  • Streaming water
  • Slippery (according to EN 15518-3)

Subject to technical modifications without prior notice.

  • Surface temperature

    • Surface temperature

      -40…+75°C

    • Accuracy

      from -10°C to +10°C: ±0.1°C (according to EN 15518-3) otherwise: ±0.5°C

    • Resolution

      0.1°C

  • Water film thickness

    • Water film thickness

      0… 10 mm

    • Accuracy

      ±15%

    • Resolution

      0.01 mm

  • Freezing point temperature

    • Freezing point temperature

      -30… 0°C

    • Accuracy

      -5°C to 0°C: ±0.5°C
      otherwise: ±15%

    • Resolution

      0.1°C

  • Thawing agent types

    • Sodium Chloride (NaCl)
    • Calcium Chloride (CaCl₂)
    • Magnesium Chloride (MgCl₂)
    • Potassium Acetate (C₂H₃KO₂)
    • Potassium Formate (CHKO₂)
  • Residual salt

    • Residual salt

      0… 100%

    • Accuracy

      ±15%

    • Resolution

      1%

  • Salt quantity

    • Salt quantity

      0… 100 g/m2

    • Accuracy

      ±15%

    • Resolution

      1 g/m2

  • Underground temperature

    • Underground temperature 1x or 2x (optional)

      -40… +75°C

    • Accuracy

      ±0.1°C

    • Resolution

      ±0.1°C

    • Depth

      max. 430 mm (longer on demand)

  • Alarms generated by the sensor

    • A1 - Winter conditions
    • A2 - Decision alarm
    • A3 - Critical alarm
  • Communication

    • Interface

      RS485

    • Protocol

      Boschung proprietary or open text protocol using ASCII codes

  • Stand-alone casing

    • Stand-alone casing

    • Integrated cable

      Standard: 30 m, longer on demand

    • Cable type

      specific: one pair 1.5 mm2 (power supply) + one pair 0.5 mm2 (RS485)

    • Cable splicing

      up to 600 m

    • RS485 extension cable (recommended)

      twisted pair, shielded, ø 0.53 mm

    • Dimensions

      ø90 mm x 42 mm

    • Weight (with standard cable)

      3.6 kg

  • Econ case

    • Econ case

    • Integrated cable

      Standard: 30 m, longer on demand

    • Cable type

      specific: one pair 1.5 mm2 (power supply) + one pair 0.5 mm2 (RS485)

    • Cable splicing

      up to 600 m

    • RS485 extension cable (recommended)

      twisted pair, shielded, ø 0.53 mm

    • Dimensions

      ø135 mm x 51 mm

    • Weight (with standard cable)

      4.0 kg

  • Airport case

    • Airport case

    • Cable type

      specific: one pair 1.5 mm2 (power supply) + one pair 0.5 mm2 (RS485)

    • Cable splicing

      up to 600 m

    • RS485 extension cable (recommended)

      twisted pair, shielded, ø 0.53 mm

    • Dimensions

      330 x 154 x 43.2 mm

    • Weight (with standard cable)

      7.8 kg

  • Electrical characteristics

    • Power supply

      24 to 48 VDC

    • Consumption

      < 0.5 W @ 12 VDC

  • International standards

    • EMC compatibility
    • EN 61000-6-1

      (immunity / residential environment)

    • EN 61000-6-2

      (immunity / industrial environment)

    • EN 61000-6-2

      (immunity / industrial environment)

      • ESD: EN 61000-4-2 with ±25 kV (instead of 8 kV)
      • Burst: EN 61000-4-4 with ±4 kV (instead of 1 kV)
      • Surge: EN 6100-4-5 with ±2 kV (instead of 1 kV)
    • EN 61000-6-3

      (emission / residential environment)

    • EN 61000-6-4

      (emission / industrial environment)

  • Environmental characteristics

    • Operating temperature

      -40… +80°C

    • Enclosure rating

      IP68

    • MTBF

      60’000 h

    • Chemical resistance

      Excellent resistance to chemical agents

Are you looking for an active Ice Early Warning System?

Boschung RWIS, Weather Stations, Surface Sensors, Highway
Close

Enquire about the IT-SENS

Receive advice about product specifications and find the right Boschung vehicle and equipment for your needs.

This field is required.
This field is required.
This field is required.
This field is required.
This field is required.
This field is required.
This field is required.
Submit