IT-ARCTIS

Active pavement sensor for freezing point measurement

With the active technology, the pavement sensor installed directly into the surface will automatically cool down its surface until freezing occurs, measuring the temperature of ice formation. By comparing the surface temperature with the freezing point temperature of the moisture, the degree of protection is known regardless of the type of chemical already applied.

  • Situation
    • Boschung
      Airport
    • Boschung
      Highway and Road
    • Boschung
      City and Municipality

Specifications

Measurements

  • Freezing point temperature

    -30… 0°C

  • Accuracy

    from -15°C to +0°C: ±0.5°C otherwise: ±1.5°C

  • Resolution

    0.1°C

Subject to technical modifications without prior notice.

  • Communication

    • Interface

      RS485

    • Protocol

      Boschung proprietary or open text protocol using ASCII codes

  • Electrical characteristics

    • Power supply

      24 to 48 VDC

    • Consumption

      < 0.5 W @ 24 VDC peak : 16 W (30m cable)

  • International standards

    • EMC compatibility
    • EN 61000-6-1

      (immunity / residential environment)

    • EN 61000-6-2

      (immunity / industrial environment)

    • EN 61000-6-2

      (immunity / industrial environment)

      • ESD: EN 61000-4-2 with ±25 kV (instead of 8 kV)
      • Burst: EN 61000-4-4 with ±4 kV (instead of 1 kV)
      • Surge: EN 6100-4-5 with ±2 kV (instead of 1 kV)
    • EN 61000-6-3

      (emission / residential environment)

    • EN 61000-6-4

      (emission / industrial environment)

  • Environmental characteristics

    • Operating temperature

      -40… +80°C

    • Enclosure rating

      IP68

    • MTBF

      60’000 h

    • Chemical resistance

      Excellent resistance to chemical agents

  • Stand-alone casing

    • Stand-alone casing

    • Integral cable

      Standard: 30 m, longer on demand

    • Cable type

      specific: one pair 1.5 mm2 (power supply) + one pair 0.5 mm2 (RS485)

    • Cable splicing

      up to 600 m (depending on power supply)

    • RS485 extension cable (recommended)

      twisted pair, shielded, ø 0.8 mm

    • Dimensions

      ø90 mm x 42 mm

    • Weight (with standard cable)

      4.2 kg

  • Econ case

    • Econ case (road application)

    • Integral cable

      Standard: 30 m, longer on demand

    • Cable type

      specific: one pair 1.5 mm2 (power supply) + one pair 0.5 mm2 (RS485)

    • Cable splicing

      up to 600 m (depending on power supply)

    • RS485 extension cable (recommended)

      twisted pair, shielded, ø 0.53 mm

    • Dimensions

      ø135 mm x 51 mm

    • Weight (with standard cable)

      4.6 kg

  • Airport case

    • Airport case

    • Cable type

      specific: one pair 1.5 mm2 (power supply) + one pair 0.5 mm2 (RS485)

    • Cable splicing

      up to 600 m (depending on power supply)

    • RS485 extension cable (recommended)

      twisted pair, shielded, ø 0.53 mm

    • Dimensions

      330 x 154 x 43.2 mm

    • Weight (with standard cable)

      8.4 kg

Are you looking for an active Ice Early Warning System?

Boschung RWIS, Weather Stations, Surface Sensors, Highway